beautypg.com

Fireplace installation – Dimplex DF2426SS User Manual

Page 9

background image

9

Fireplace Installation

Option #1 - The power cord can

be lead from behind the trim

and along the wall to an outlet

near the fireplace.

Option #2 - A new outlet can be

installed inside the new frame

construction. Plug the unit into

a 15 Amp/120 Volt outlet. If

the cord does not reach, you

may use an extension cord

rated for a minimum of 1875

Watts.

Option #3 - Hardwire

Wire a dedicated, properly

1.

fused circuit with 120 Volt,

15 Amp rating. Allow up to

eight (8) feet of service cable

for connecting power supply

to junction box on fireplace

when installing after finishing

wall.

CAUTION: Use two

conductor, non-metallic sheath

cable with ground wire (3 wires

total) for the incoming power

supply on fireplace inserts. use

appropriate wire to meet local and

national electrical codes for rated

power consumption.

remove the outer jacket and

2.

strip the individual conductor

from the end.

Loosen the screw securing

3.

the junction box cover and

remove the cover.
Take the cables out from the

4.

junction box, loosen the two

wire twist nuts and remove

the cord set (Figure 2).
Route the power supply wire

5.

through the knockout on

supplied alternative junction

box cover and secure with

Figure 2

Figure 3