TROUBLESHOOTING TIPS

FUSE REPLACEMENT

To change the fuse, remove the power cord and pull the fuse holder straight out. Remove

the old fuse from the holder and replace it with the supplied spare. Replace the fuse holder

into the machine and check for proper operation.

CARE and CLEANING

With time and use, the clamping surfaces of your machine may become oily or dirty and

result in string or clamp slippage while stringing. Periodic cleaning of the following parts is

recommended.

String Clamps

Clean the inside gripping surfaces of the string clamp jaws by inserting a cloth or pipe cleaner

soaked with isopropyl alcohol between the jaws and rub back and forth. If the build-up is

excessive, dismantle the string clamp jaws to expose the gripping surfaces by removing the

adjustment screw. Using a small nylon brush, (such as a toothbrush), scrub the inside

surfaces until all debris is removed. Clean the jaws with isopropyl alcohol and re-assemble.

String Clamp Base

Clean the base of the clamps and the top of the turntable with isopropyl alcohol.

String Gripper

Follow the same procedure for cleaning the string clamps.

String tension too tight or too loose.

- Check tension using a tension

calibrator and adjust machine calibra-

tion if necessary

Electrical system does not function.

- Check power source.
- Check power cord connection.
- Check stringing machine fuse.
- Check for proper voltage setting (110/

220) of machine.

- Call customer service.

String clamp base slips on turntable.

- Adjust Clamp Base Locking Nut.

String slips in gripper.

- Clean gripper jaws.
- Make sure string is wrapped over top

jaw of gripper prior to inserting between

gripper jaws.

String slips in clamps.

- Adjust gap between jaws.
- Clean clamp jaws.

PROBLEM