beautypg.com

Planning guide – Dacor Preference Gas Cooktops User Manual

Page 2

background image

PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

4.10

SGM304, SGM365, SGM466

13"

(330mm)

Max.

A

3 1/8" Min.

(79mm)

30"

(762mm)

Min.

Clearances to Combustibles

18"

(457mm)

Min.

Model

“A”

Minimum

“A”

Maximum

SGM304

30” (762mm)

36” (914mm)

SGM365

36” (914mm)

42” (1067mm)

SGM466

48” (1219mm)

54” (1372mm)

Model

“B”

Minimum

SGM304

29” (737mm)

SGM365

35 1/4” (895mm)

SGM466

46” (1168mm)

1/4” (6mm)

Mimimum clearance

to combustible

surfaces

B

Under Cabinet Clearances - Front View

30”, 36”, 46” Wide,

Preference™ Gas Cooktops

2/2

NOTES:

1. Factory installed liquid propane (LP) special

ordered.

2. Cooktop is supplied with a 48” (1219mm) power

cord, with a three prong grounded plug.

3. Utilities are located in the right rear corner of the

cooktop.

4. See the Combination Installation (CI) section if

installing with a downdraft, wall oven, or warming

oven.

Revised

07/18/08

SGM304

SGM365

SGM466

SGM304LP

SGM365LP

SGM466LP

Gas Type

Natural Gas

LP Gas

Manifold

Pressure

5” Water Column

10” Water

Column

Min. Gas Supply

Pressure **

6” Water Column

11” Water

Column

Total Connected

Load

0.25 Amps

(0.03 kW)

0.25 Amps

(0.03 kW)

Circuit

Requirement

120 Vac,

60 Hz, 15 Amp

120 Vac,

60 Hz, 15 Amp

All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.