4.3
36”, 48” Wide,
Epicure™ Gas Cooktops
EG366, EG486
1/4
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required
Total Connected Load
120VAC
60Hz, 15A
24.0W (0.2A)
GAS SUPPLY PRESSURE REQUIREMENTS
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
Combustible
rear wall
Backsplash mandatory
if gap from back of
cooktop to combustible
wall is less than 2 1/2”
SIDE VIEW WIth BACkSPLASh
Combustible
rear wall
2 1/2” (64mm) Min. to
combustible rear wall
SIDE VIEW
A
ProDUCt DImENSIoNS
COOKTOP WIDTH (A)
EG366
35 7/8” (911mm)
EG486
47 7/8” (1216mm)
All tolerances: +1/16”, -0 (+1.6mm, -0)
SIDE VIEW
A
Rear of trim to front of knobs
B
Rear of trim to front of bull nose
C
Rear of trim to front of control panel
D
Bottom of chassis to bottom of trim
4” (102mm)
5/8” (16mm)
D
7 3/4”
(197mm)
B
27” (686mm)
A
28” (711mm)
C
26” (660mm)
Revised
01/30/08
Power Cord
29” (737mm) long