6 Connect Request
The Connect request will instruct the IT-AS411 to connect the specified input to the
output. The user can also inquire as to which input is currently connected. The format for 
the Connect request is as follows: 
 
CON
input number
 
Syntax: CON <”1”|”2”|”3”|”4”> | <”?”>
Where: 
CON 
Connect
Request
Header
input number
Input to connect, one ASCII character 1 to 4
“?”
? for inquiring configured connection
 
Example 1: 
 
CON 3 <cr>
Instructs the IT-AS411 to connect input 3 to the output. 
 
Example Response: 
 
ACK
 
 
This response means that the command has been received and is valid.
 
Example 2: 
 
CON 4<cr>
Instructs the IT-AS411 to connect input 4 to the output. 
 
Example Response: 
 
ACK
 
 
This response means that the command has been received and is valid.
 
 
Error Example: 
 
CON 6
Instructs the IT-AS411 to connect input 6 the output, which is invalid since there
are only 4 inputs. 
 
Error Response: 
ERR: CON <”1”|”2”|”3”|”4”> |<”?”>
 
Connect Inquiry 
If the user wishes to know what input is connected currently, the user would insert
a “?” in place of the input number, an Inquiry would look like this: