10
Acctiva 12/24 - 20
(continued)
Acctiva 12/24 - 20
On-time
100 %
Charging characteristic
IUoU
Protection*)
IP 31
Operating temperature **)
-10°C to +50°C
14°F to 122°F
Storage temperature
-25°C to +80°C
-13°F to 176°F
EMC Class
EN 61000-6-4 (Class A)
EN 61000-6-2
EN 61000-3-2
Weight
2020 g
4.45 lb.
Dimensions l x w x h
285 x 70 x 142 mm
11.2 x 2.8 x 5.6 in.
NOTE! For indoor use only, do not expose the charger to rain or snow
Setup regulations:
-
Component specifications Climate class B
-
Humidity 5 % to 85 %
*)
Symbols used
Follow operating instructions
Connect battery poles correctly:
(+) red (-) black
Detonating gas is generated in the battery during charging.
Risk of explosion!
The charger heats up depending on operating conditions.
Before disconnecting the charger lead from the battery,
interrupt charging
Chargers may only be opened by a qualified electrician
Warning notices
affixed to the
charger
Avoid flames and sparks during charging.
Ensure adequate ventilation during charging.
Battery acid is corrosive.
For indoor use only.
Do not expose to rain.
**) at higher temperatures a drop in performance may occur (derating)