beautypg.com

Controls and indicators – Fronius Agilo 360.0-3 TL User Manual

Page 56

background image

54

Controls and indicators

Controls and indi-
cators

Item

Description

(1)

Display
for displaying values, settings and menus

Monitoring and status LEDs

(2)

General status LED (red)
on steady
-

if a status message is being displayed on the monitor

-

if the process of feeding energy into the grid is interrupted

-

while error handling (the inverter waits for an acknowledgement or for an
error to be rectified)

(3)

Startup LED (orange)
on steady if
-

the inverter is in its automatic startup or self-test phase (as soon after sun-
rise as the solar modules are delivering sufficient power)

-

the inverter has been switched to standby mode in the setup menu (= feed-
ing energy into the grid switched off manually)

-

the inverter software is being updated

(4)

Operating status LED (green)
on steady,
-

if the PV system is working correctly after the inverter's automatic startup
phase

-

all the time while energy is being fed into the grid

Function keys - allocated different functions depending on the selection:

(5)

'Left/up' key
for navigating to the left and up

(6)

'Down/right' key
for navigating down and to the right

(7)

'Menu/Esc' key
for switching to the menu level
for quitting the setup menu

(8)

'Enter' key
for confirming a selection

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

This manual is related to the following products: