(4)Designation and Functions of Operation Panel
No.
Designation/Indication Function
1
Fold type key
Six folding types can be input and stored.
2
Test key
Test folding of two sheets is performed.
3 Start/Stop
key
Operation starts and if pushed again, the machine
stops.
4 Clear/Reset
key
Clearing the indication of the counter / resetting
an error.
5
Store key
Fold position after adjustment is stored.
6
Counter input mode
lamp
It is on when batch counting is indicated on the
counter.
7 Select
key
Used for selecting the indication of the counter, the
position of the stopper stud of Table 1 and 2 and
paper length.
8
Perforation mode lamp
It is on when the optional sewing unit is installed.
9 +/-
key
Used for adjusting the position of the stopper of
Table 1 and 2 and paper length
10 Speed
adjust key
Used for adjusting the speed.
11 Numerical
key
Used for inputting the batch count and the
length of non-standard-size paper
12 Counter
The number of sheets, the position of the stopper
pin of Table 1 and 2, paper size are indicated.
13 Check
lamp
It is on when paper stock runs short, or indicates a
Place where paper feed trouble occurs.
14 Table 1 stopper move
mode lamp
It is on when the position of stopper of Table 1 is
Adjusted.