Table 16. Supported Power Profiles
Static MAX
Performance
DBPM Disabled ( BIOS sets P-State to MAX)
Memory frequency = Maximum Performance
Fan algorithm = Performance
OS Control
Enable OS DBPM Control (BIOS exposes all possible P states to OS)
Memory frequency = Maximum Performance
Fan algorithm = Power
Active Power
Controller
Enable Dell System DBPM (BIOS will not make all P states available to OS)
Memory frequency = Maximum Performance
Fan algorithm = Power
Custom
CPU Power and Performance Management:
Maximum Performance | Minimum Power | OS DBPM | System DBPM
Memory Power and Performance Management:
Maximum Performance |1333Mhz |1067Mhz |800Mhz| Minimum Power
Fan Algorithm
Performance | Power
Table 17 details power management state transitions.
Table 17. Power Management State Transition
Wake Up Events
States Can Wake From
RTC
OS-S4*
Power Button
S5
RI#
Not supported
PME#
S5
KB
Not supported
MOUSE
Not supported
USB
Not supported
WOL
OS-S4*
*S4 has OS support only.