9
Maintenance
– continued –
. Take heed of the danger note on page 5.
. Cut off power supply to actuator
1
.
3. Undo hexagon screws
7
and remove actuator and coupling
8
.
4. Unscrew the hexagon nut
T
and detach control lever
U
with the aid of a pulling device.
5. Undo stuffing box screws
A
, remove stuffing box gland
C
, scale plate
B
, disk springs
D
and
spring sleeve
E
.
6. Unscrew nozzle stem
R
and pull is out of the valve body.
7. Unscrew locking screw
P
and remove gasket
Q
.
8. Unscrew sealing plug
O
and remove gasket
N
.
9. Use a brass drift punch d = 4.8 mm to force out the internals
F
to
J
,
Fig. 14
0. Clean and, if required, exchange valve body
K
and internals.
. Apply glue type “Loctite
®
60” to seat bushing
J
and put it in place. Insert stage bushing
I
.
. Align wearing bushing
H
in such a way that the groove is on the longitudinal axis of the locking
screw
P
.
3. Screw in the locking screw
P
together with gasket
Q
and tighten it with a torque of
5 Nm (DN 5 – 3) or 11 Nm (DN 40, 50) when cold.
4. Align and insert the guide sleeve
G
in such a way that the groove on the longitudinal axis
is on the locking screw
P
,
Fig. 12.
5. Insert new wiper rings and packing rings
F
as shown,
Fig. 12.
6. Apply lubricant (type WINIX
®
00) to the thread and sealing surface of the nozzle stem.
7. Insert nozzle stem
R
and screw it into the guide sleeve
G
by two turns.
8. Insert spring sleeve
E
and disk springs
D
in the shown sequence.
9. Put scale plate
B
and stuffing box gland
C
in place and tighten stuffing box screws
A
slightly.
0. Screw out nozzle stem
R
by half a turn and fasten stuffing box screws
A
with a torque of
7 Nm (DN 5 – 3) or 11 Nm (DN 40, 50).
. Turn nozzle stem
R
into the closed position, applying a torque of
7 Nm. Put control lever
U
in
place and align scale
S
with the scale plate
B
such that the diamond-shaped marker “0” is in the
middle of the scale plate.
Changing packing and internals of BAE 46, BAE 47
WINIX
®
00
is a registered trademark of WINIX GmbH, Norderstedt
LOCTITE
®
is a registered trademark of HENKEL KgaA, Düsseldorf
Changing packing and internals of BA 46, BA 47
– continued –
5. Insert nozzle stem
R
and screw it into the guide sleeve
G
by two turns.
6. Insert spring sleeve
E
and disk springs
D
in the shown sequence.
7. Put scale plate
B
and stuffing box gland
C
in place and tighten stuffing box screws
A
slightly.
8. Screw out nozzle stem
R
by half a turn and fasten stuffing box screws
A
with a torque of
7 Nm (DN 5 – 3) or 11 Nm (DN 40, 50).
9. Turn nozzle stem
R
into the closed position, applying a torque of
7 Nm. Put control lever
U
in
place and align scale
S
with the scale plate
B
such that the diamond-shaped marker “0” is in the
middle of the scale plate.
0. Screw hexagon nut
T
onto the threaded part of the nozzle stem
R
and tighten with a torque of
20 Nm while holding the control lever.
. Screw sealing plug
O
together with gasket
N
into the valve body and tighten with a torque of
130 Nm or screw in the sample valve with the gasket according to the instructions given by the
manufacturer.