2.1 Initial Inspection and Storage Instructions
c
WARNING: Read this installation and maintenance manual carefully and completely before attempting to
store the operator. If an electric actuator is attached to the WG manual operator, be aware of the electrical
hazards. Consult the electric actuator installation and maintenance manual for guidance.
2.2 Inspection and Recording
Upon receipt of the operator, inspect the condition of the equipment, and record nameplate information.
1. Carefully remove operator from shipping carton or skid. Thoroughly examine the equipment for any physical
damage that may have occurred during shipment. If damaged, immediately report the damage to the transport
company.
2. A nameplate is attached to each operator with the following information:
• Operator size
• Assembly position
• Order number
• Serial number
• Customer tagging
Record this information for future reference, e.g., ordering parts, or obtaining further information.
2.3 Storage Procedure
NOTE: The following is the recommended storage procedure to retain maximum product integrity during storage.
Failure to comply with recommended procedure will void the warranty.
Storage (less than one year)
Store operators on wooden skids to protect the machined mounting flange. Place the wooden skids containing the
operators in a clean, dry, protected warehouse. If the operators must be stored outside, they must be covered in
polyethylene protection with silica gel crystals to absorb moisture. If an electric actuator is attached to the WG, refer
to the storage procedures in its respective manual for appropriate storage procedures. Rotate input shafts every three
months to mix the lubricant.