The Apex 5100 I/P Module converts 4-20 mA current signals into 3-15 psi pneumatic signals needed by the
Apex 5000 Positioner. A controller card compares the input signal with an electrical pressure feedback signal
and outputs voltage, which is applied to a coil.
The coil voltage varies a magnetic field strength which influences a metallic diaphragm. This diaphragm
throttles air flow out of the positioner input chamber (supplied by the internal regulator). As voltage and field
strength increase, the diaphragm moves closer to the coil nozzle, reducing air flow and increasing positioner
input chamber pressure.
The controller circuit board features temperature compensation and input signal filtration to provide accurate
3-15 psi output signals.