5 disassembly of 5:1 spur gear attachment for mt-4, 6 reassembly of 5:1 spur gear attachment for mt-4 – Flowserve MT Bevel Gearboxes IOM User Manual
Page 25

25
Limitorque MT Series FCD LMENIM4201-00 – 06/10
flowserve.com
6.4.5 Disassembly of 5:1 Spur Gear Attachment for MT-4
(Piece numbers refer to Figure 6.7 and Table 6.7).
1. Remove the Socket Head Cap Screws (piece #217) and Lockwashers (piece #216) to remove the
Housing (piece #201).
2. Remove the Housing complete with the Input Shaft and Pinion (piece #202) and Idler Gear
(piece #203).
3. Remove the Hex Head Cap Screw (piece #215), Lockwasher (piece #214), and Flat Washer
(piece #213).
4. Remove the Output Gear (piece #204).
5. Remove the Hex Head Cap Screw (piece #218) and Lockwasher (piece #216).
6. Remove the Adapter Plate (piece #200) and O-ring (piece #211).
7. Continue disassembly as detailed in Section 6.2, Disassembly and Reassembly of MT-4.
6.4.6 Reassembly of 5:1 Spur Gear Attachment for MT-4
(Piece numbers refer to Figure 6.7 and Table 6.7).
1. Install the O-ring (piece #211) and Adapter Plate (piece #200), using the Hex Head Cap Screws
(piece #218) and Lockwashers (piece #216).
2. Install the Output Gear (piece #204).
3. Install the Flat Washer (piece #213), Lockwasher (piece #214), and Hex Head Cap Screw
(piece #215).
4. Install the Idler Gear (piece #203) and the Input Shaft and Pinion (piece #202) into the Housing
(piece #201).
5. Apply liquid gasket to the Adapter Plate flange and install the Housing assembly (piece #210, #202,
and #203), using the Socket Head Cap Screws (piece #217) and Lockwashers (piece #216).