1 to replace the stem nut only – Flowserve SMB Series Electric Actuators User Manual
Page 57

57
SMB Series/SB Series Installation and Maintenance FCD LMENIM1401-04-AQ – 01/15
flowserve.com
Table 7.2 – SMB-00 Parts List (continued)
Piece
Quantity
Description
141
4
Flat Head Machine Screw
143
3
Pipe Plug (Only 1 shown)
144
4
Pipe Plug (Only 3 shown)
148
1
Drive Sleeve Bevel Gear
154
2
Socket Head Cap Screw
156
1
Key
157
6
Socket Head Cap Screw
158
6
Lockwasher
159
4
Lockwasher
160
4
Round Head Machine Screw
162
4
Flat Head Socket Cap Screw
164
1
Key
165
2
Socket Head Set Screw
166
1
Socket Head Cap Screw
167
1
Lockwasher
168
2
Key
169
1
Key
170
1
Socket Head Set Screw
173
1
Hex Head Cap Screw
174
4
Stud
175
4
Hex Nut
176
4
Lockwasher
177
1
Socket Head Set Screw
178
1
Key
7.3 SMB-0, 1, 2, 3 and 4
c
WARNING: See Section 4.1 and 4.2 on Safety Precautions and Safety Practices before
proceeding with disassembly.
7.3.1 To Replace the Stem Nut Only
c
WARNING: Do not remove the Locking Nut (piece #30) with the actuator under load or with valve
under pressure.
a
CAUTION: If valve must be left in service while the stem nut is replaced, the valve stem must be
locked in such a way as to prevent any movement of the valve stem.
1. Remove Locking Nut (piece #30). The locking nut is staked in two places; locate the stakes and
spot with a drill.
2. Clean all metal particles.
3. Lift Stem Nut (piece #20) out of the top of the actuator.
If the actuator is mounted on a valve having a threaded stem, and stem nut removal is required,
proceed as follows:
1. Remove Locking Nut (piece #30).