background image

1

NORDSTROM HYPREGUN-PLUS 5Q

Flow Control

Nordstrom Valves

Flow Control

Nordstrom Valves

Care and Maintenance

Suggested

Hypregun-Plus 5Q Care

The following suggestions will ensure efficient and continued

operation of the Hypregun-Plus 5Q.
1. Avoid damage to the thin walled cylinder surrounding the

piston of the air motor. Imperfections in this cylinder will

reduce the effectiveness of the gun and shorten its life.

2. Handle the Hypregun-Plus 5Q with care. Prevent any bending

or denting of the pistons or operating parts.

3. Use a clean, dry air source. If air is wet, use a filter on the air

line to remove the water. Install an oiler in the air supply line

using light oil in summer and methanol in the winter.

4. Do not use over 125 psi (8.6 bar) air supply pressure. The

gun will work best between 100 psi (6.9 bar) and 125 psi

(8.6 bar).

5. Always use the can shield and five-quart (4.7 litre) cans that

are crimped and welded. The vertical welded seam on the

can should be placed opposite the opening on the shield. If

the opening on the shield is placed over the seam in the can,

the can seam may separate from the pressure created by the

piston.

6. CAUTION - When inserting a new five-quart (4. litre)

can of sealant, be extremely careful. Keep fingers

clear as the follower plate descends into the sealant

container.

7. Be sure to bleed or vent the Hypregun-Plus 5Q before using.

The more the curvature of the mounded sealant matches the

curvature of the follower plate, the less air will be entrapped

when changing cans. The relief valve (64, Section B-B) should

be opened until a steady stream of sealant is obtained. If the

pressure gauge needle continues to bounce, remove the valve

screw (63, Figure 1) to free entrapped air in that area and, in

rare occasions, remove the pressure gauge to be sure there

is no air entrapped in the connection to it. Improper bleeding

is indicated by a very bouncy action of the pressure gauge

needle at relatively low pressures. If this continues, additional

bleeding is necessary.

8. Store the Hypregun-Plus 5Q and sealant in a reasonably warm

place so that not only the gun but the sealant is at an operable

temperature.

Repair Reassembly

There are two places in the reassembly of the Hypregun-Plus

5Q pumping mechanism where the parts should not be rigidly

assembled:
1. When the piston and cylinder (42, Section C-C) are attached

to the air motor piston rod (37, Section C-C), they should only

be hand tight (not wrench tight), the holes aligned, and the

roll pin installed to secure in place.

2. In assembling the primer rod and foot valve assembly (45,

Section C-C) into the piston, it should be pinned in place

with roll pin (38, Section C-C) before it becomes tight. There

should be some “wobble” evident for self-alignment of the

parts. The primer rod and foot valve assembly (45, Section

C-C) and valve seat (47, Section C-C) should be replaced as

a single unit.