4.2.6 Remove the rotor retaining

ring from the sleeve and re-

move the rotor from the sleeve.

4.2.7 Remove the O-rings from the

sleeve and discard. Be careful

not to mar the sleeve.

4.2.8 Pull the stator from the gland

ring bore and remove and dis-

card the springs. See Figure 9.

4.2.9 Remove the stator mounting

O-ring and face gasket, from

the gland and discard.

Note: Parts which should be discarded include the O-rings, gasket,

springs, centering tabs and centering tab cap screws and set screws.

Parts which may be reused if in satisfactory condition include the sleeve,

gland and sleeve collar.

Parts which may be reconditioned by an authorized Flowserve repair

facility include the rotor and stator.