beautypg.com

Flowserve P-50 Durametallic User Manual

Page 10

background image

10

4.3.2 Coat all sleeve O-rings with

silicone lubricant and install

them onto the sleeve. See

Figure 11.

Note: Earlier versions of the P-50

utilized a different pin drive design

which does not require O-ring. If the

pin in the sleeve is not grooved for an

O-ring, the O-ring will not be used.

Note: If Duraflon encapsulated

O-rings are to be installed, contact

your local Flowserve repair facility for

proper installation.

4.3.3 Install the rotor onto the sleeve

aligning the drive slot with the

pin. See Figure 12.

4.3.4 Install the rotor retaining ring.

Be careful not to nick, scratch or

damage the rotor face.

4.3.5 Place the sleeve/rotor assem-

bly rotor face up and clean the

face with alcohol.

See Figure 13.

4.3.6 Install new springs into the

stator, clean the stator face

with alcohol and place it down

onto the rotor. Be sure the

springs are placed in the proper

(deeper) holes. See Figure 14.

Figure 12

Figure 13

Figure 11

Figure 14