Description – Flowserve SLD User Manual
Page 2
2
SLD Installation Instructions
The following instructions are designed to simplify the installation of a typical
SLD (Synthetic Lubrication Device) seal support system. By reading this manual
and following its guidelines, seal performance can be improved by helping to
reduce the chances of premature failure attributed to improper installation or
use. In addition to these instructions, consult the seal assembly drawing included
for your specific seal design, materials of construction, critical dimensions,
and any auxiliary piping connections. If any problems arise during installation,
Do Not Try to Force Anything.
These instructions are written for trained, experienced technicians who are
familiar with the basic principles and tools involved in the installation, care
and service of mechanical seals and seal support systems.
A complete reading of these instructions by personnel in contact with
the equipment is essential to safety. Incorrect installation, operation
or maintenance can result in personal injury or death to personnel and
damage to the equipment.
Description
The SLD Seal Support System is a stand-alone system that dispenses a supply
of synthetic lubricant to the atmospheric side of mechanical seal faces during
periods of marginal equipment operation. Ideally suited for single mechanical
end face seals incorporating two hard carbide faces and a quench containment
device (QCD), it is primarily utilized in water based slurry applications when
operating flushless mechanical seal designs. The SLD Seal Support System
allows synthetic lubricant to be wicked between the faces due to centrifugal
action during periods of uncontrolled equipment cavitation or periods of
unintentional dry running. When proper dispensing rate is selected the SLD Seal
Support System may be able to take the place of a continuous water quench
traditionally used only as a means to help prevent seal face damage associated
with periods of starved operation. The SLD Seal Support System is not intended
to supply added cooling or able to dissolve scaling products that a continuous
water quench may provide. With a properly installed and functioning SLD Seal
Support System, friction generated heat levels leading to face damage have not
been observed in laboratory tests for periods of up to 30 minutes when normal
liquid pumpage is not present.
The SLD Seal Support System does not require compressed air, electricity, or
external water in order to function correctly. This makes it ideal for equipment
having frequent automatic start/stop sequences or for installations at remote
field locations. The SLD Seal Support System should be a consideration for
use with new equipment that will be sitting at a job site for extended periods of
time prior to being placed into operation. The SLD allows for hand rotation of
shafts as requested by many bearing manufacturers to reduce scoring effects
to mechanical seal faces during the procedure. The SLD Seal Support System
can also help keep dirt, dust, and moisture debris from the atmosphere from