bellows assembly into place using finger pressure

only. See Figure 12.

For sizes > 2.750 inch (70 mm)

align the drive pin

on the sleeve with the drive slot on the bellows

assembly and press the bellows assembly into

place using finger pressure only.

Caution

: Do not over-compress the bellows

assembly.

6.4 Clean the sealing face of the bellows assembly

[79] to remove any dirt, dust, fingerprints, grease

or any other residue using alcohol on a clean cloth

or tissue.

6.5 Place the inboard stationary face O-ring [13] into

the inner gland [11]. See Figure 13.

6.6 For sizes ≤ 2.750 inch (70 mm) install the vibration

dampener [183.1] onto the inner gland surface

where the stationary face [14] will be installed. See

Figure 14.

For sizes > 2.750 inch (70 mm)

install the square-

headed pin [5] into the hole on the inner gland

where the stationary face [14] will be located. Cut

a 0.250 inch (6 mm) slot in the vibration dampener

[183]. See Figure 15. Install onto the inner gland

surface where the stationary face will be installed

with the slot positioned where the drive pin is

located.

6.7 For sizes ≤ 2.750 inch (70 mm) align the flats on

the inboard stationary face [14] with the flats on

the inside of the inner gland [11], and press the

stationary face in place using finger pressure only.

See Figure 16.

For sizes > 2.750 inch (70 mm)

ensure that the slot

on the stationary face [14] and the square-headed

pin [5] are aligned and install into the inner gland

[11] using finger pressure only.

6.8 Clean the sealing face of the stationary face [14]

to remove any dirt, dust, finger prints, grease or

any other residue using ethyl alcohol on a clean

cloth or tissue.

6.9 Place the inner gland assembly face down onto the

sleeve assembly. See Figure 17.

Figure 12

Figure 13

Figure 14

Figure 17

Figure 15

Figure 16