beautypg.com

Flowserve ISC2 Dual metal bellows sea User Manual

Page 11

background image

11

Figure 27

Figure 28

Figure 29

holding the collar in compression, tighten the

quarter-dog set screws [57.1] into the holes in

the sleeve until snug. If the seal does not contain

quarter-dog set screws then tighten the set

screws [57] into the sleeve [1]. See Figure 27.

Caution:

Over tightening will cause

distortion of the sleeve assembly [1]. Check

integrity of the sleeve with a plug of the

appropriate size to ensure no distortion has

occurred.

6.22 Install the sleeve O-ring [19] into the ID groove of

the sleeve assembly. See Figure 28.

6.23 The cartridge seal assembly is now ready for

testing.

6.24 Adhere the gland gasket [18] to the inner gland

gasket surface with a spray adhesive such as 3M

Super 77

®

. See Figure 29.

6.25 Permanently mark the seal type ISC2-BB, seal

size and gland ring material clearly on the gland

surface. See Figure 1 for placement location.

ISC2-BB

M060

C-276

Example

inch

marking

ISC2-BB

1.875

316 SS

Example

metric

marking