DS USER INSTRUCTIONS ENGLISH 71576283 - 02/13
02
Page 29 of 36
flowserve.com
Viscosity grade ISO 46
Ambient temperature
Bearings temperature 80 °C (176 °F) maximum
TABLE OF EQUIVALENCE AND CHARACTERISTICS
OF RECOMMENDED OILS
MANUFACTURER TYPE
CHARACTERISTICS
BP
ENERGOL
HLP
46
ELF
TURBELF
SA
46
ESSO
TERESSO
46
MOBIL
DTE
MEDIUM
SHELL
TELLUS
T
37
TOTAL
PRESLIA
46
TOTAL
AZOLLA
ZS
46
Density at 15 °C (59 °F)
0.885
0.881
0.868
0.878
0.87
0.872
0.877
Viscosity at 40 °C (104 °F).cSt
45
48.6
43
43
46
46
46
Viscosity at 50 °C (122 °F).cSt
30
31.5
29.4
28
30
29.5
30
Viscosity at 100 °C (212 °F).cSt
6.9
7.1
6.7
7
6.9
6.9
6.8
Pour-point °C / °F
- 30
- 22
- 27
- 17
- 12
10.4
- 15
5
- 30
- 22
- 12
10
- 21
- 6
Flash-point °C / °F
210
410
220
428
220
428
220
428
214
417
230
446
230
446
Fire-point °C / °F
240
464
252
486
280
536
240
464
245
473
Aniline point °C / °F
99
210
102
216
110
230
102
216
109
228
101
214
101
214
Viscosity index
105
106
109
105
113
100
100
Acid value
0.2
0.6
0.2
0.13
0.7
0.1
0.7 to 1.2
Color
1 ½
2
1
2
2
1 ½
1
Antierosion additives
yes
yes
yes
yes
yes
Foam inhibitors
yes
yes
yes
yes
yes
yes
yes
Anticorrosion additives
yes
yes
yes
yes
yes
yes
yes
Antioxidant
yes
yes
yes
yes
yes
yes
yes
Conradson carbon residue
0.01
0.2
Limits on temperature °C / °F
- 12 to
120 °C (10
to 248 °F)
- 21 to
110 °C (- 6
to 230 °F)
Saponification
< 0.5
1.2
6.2.5 Gland packing
6.2.5.1 Pump fitted with a packed gland
A well run in and correctly adjusted packing gland
requires little maintenance. If, after some time, the
leakage becomes too great, the gland should be
tightened again in order to return these to a normal
level.
If re-tightening is not possible, new packing must be
installed
6.2.5.2 Gland packing inspection and removal
a) Remove the shield guards.
b) Slide back the gland.
c) Remove the packing rings with an extractor
designed for this purpose (including the lantern
ring if it exists; note its position and its direction
of rotation).
d) Inspect the state of the sleeve surface; the
presence of many marked grooves will indicate
that it must be replaced.
e) Carefully clean the different pieces of the
packing gland.
6.2.5.3 Gland packing fitting
If the packing is supplied as cord the packing must
be cut so that the external diameter is lightly
tightened and there is an initial gap between the
sleeve and the packing ring.
For that purpose, wind the packing helically around
the shaft sleeve or a chuck of the same diameter.
(Take precautions to avoid damaging sleeve).
Example of straight cut
Example of bevel cut
Ensure a tightening on the stuffing
box housing and not on the sleeve.
SETTING OF PACKING