2 nomenclature – Flowserve FP User Manual
Page 13

FP USER INSTRUCTIONS ENGLISH 71576286 - 02/13
Page 13 of 40
The pump must be stored in a non-explosive,
ventilated location, sheltered from bad weather, dust
and vibrations.
•
Maximum working pressure at discharge
................................................................ 25 bars
•
Maximum working pressure at suction .... 16 bars
except 122-152 and 202 FP .................... 10 bars
•
Maximum pumped fluid temperature ...... 105 °C
impeller and diffuser for
CAST IRON
or
BRONZE
.
•
Minimum pumped fluid temperature ....... -10 °C
•
Maximum ambient temperature .............. 40 °C
•
Maximum solid suspension ..................... 50 g/m
3
•
Density........................................................... 1
•
Viscosity .............................................. 1 mm²/s
•
Frequency ................. 50 Hz (1450 - 2900 min
-1
)
................................... 60 Hz (1750 - 3500 min
-1
)
•
Maximum number of stages (according to
rotation speed)
3500
min
-1
2900
min
-1
1750
min
-1
1450
min
-1
50 FP
6
7
7
7
65 FP
4
6
7
7
80 FP
3
5
6
6
100 FP
3
5
6
6
122 FP
4
5
125 FP
2
3
4
5
152 FP & 202
FP
3
4
The maximum speed is shown on the
pump nameplate.
3.2 Nomenclature
Characteristics shown on the nameplate fixed on the pump are as shown below:
Each pump is supplied with the following nameplate:
Each pump unit is supplied with the following nameplate:
Mass of the set
EU Regulation 547/2012 requires the statement on a product nameplate:
•
MEI
≥
0.10 [--.-] (Between 1st January 2013 and 1st January 2015)
•
MEI
≥
0.40 [--.-] (From 1st January 2015)
Pump type
Speed of rotation
Flow rate
Year of construction +
Manufacture number
Head
Radial/thrust bearing
Mass
Maximum admissible
Pressure at 20 °C
Maximum / minimum
temperature