Flowserve TB-MAG INNOMAG User Manual
Page 36

INNOMAG® TB-
MAG™ ASME and ISO SEALLESS ENGLISH 26999988 06-14
Page 36 of 44
t)
Remove the (3) hex caps screws [6570.1] from
the bearing cap [3240] and pry the bearing cap
loose with a small flat head screw driver.
u) If the bearing isolator [4305] needs to be
replaced, the unit can be pressed out by hand.
v) Slide the shaft and front bearing out of the
bearing frame straight up until the retaining ring
[6544.1] can be seen. Using a screwdriver, lift the
retaining ring by prying under the notched end
and remove the retaining ring [6544.1] from the
assembly.
w) The shaft [2100] can now be removed from the
bearing frame. There is very little clearance
between the bearing [3011] and the bearing
frame [3200] opening. It can be very difficult to
remove if the shaft [2100] is not held perfectly
straight when pulling through the opening.
x) If the rear bearing isolator [4305] needs to be
replaced, the unit can be pulled out by hand.
y) The wave spring [6544.2] can be removed by
hand for inspection and / or replacement. If the
bearings [3011] need to be replaced, use a 3 jaw
puller to remove.