beautypg.com

Fitting the diffuser, Fitting the back pull out unit, Fitting other parts – Flowserve PVML User Manual

Page 24

background image

PVML USER INSTRUCTIONS ENGLISH 00079591 – 01/05

®


6.9.8

Fitting the diffuser


This procedure describes assembly of the diffuser into
the casing cover.

Clean the surfaces of the diffuser and the casing

cover.

Place the diffuser [1410] on the casing cover.

Make sure that the centring rim is not damaged.

Mount the hexagon head bolts [6577.1] with lock

washers [6541].

Lock the hexagon head screws [6577.1] against

the diffuser using the lock washers [6541].

6.9.9

Fitting the back pull out unit


This procedure describes assembly of the 'back pull
out' unit to the pump casing.

Clean the supporting surfaces of the casing cover

and the pump casing.

Clean internally machined surfaces which come

into contact with liquid and surfaces where there
is only a narrow gap between them and other
finished surfaces. Treat these surfaces with e.g.
Molykote G (spray or paste).

Place a new packing ring [4590.2] onto the rim of

the pump casing.

Attach lifting devices at the appropriate lifting

points. Observe the lifting instructions described in
section 2.3.

The lifting lugs fixed to the motor

are sufficient to lift the motor, but are not suitable
to lift the total unit.

Lift the casing cover above the pump casing and

make sure that the casing cover is in the correct
position in relation to the pump casing. There is
only one way for the casing cover to fit onto the
pump casing.

Carefully place the casing cover on the pump

casing. Work carefully as there is little clearance
between the diffuser and the pump casing. Also
make sure that the centering rim of the casing
cover is not damaged.

Tighten the nuts [6581.1] evenly across the casing

cover by applying the prescribed tightening torque
in accordance with table per section 6.5.

6.9.10 Fitting

other

parts

Clean the supporting surfaces of the casing cover

and the pump casing.

Connect all auxiliary pipes in accordance with

the dimensioned drawing, the “Process and
Instrumentation Diagram” (P&ID) or the
“Auxiliary Piping Arrangement Drawing”.

Reconnect the electric motor in accordance

with the instructions for use provided by the
relevant supplier.

Page 24 of 29