****** WARNING ******

• Always wear eye protection.
• When fan coil is operating,
some components are operating
at high speeds. Personal injury
can result from touching these
items with any object
• All electrical and service
access panels must be returned
and secured in their proper
place.
• Clear surrounding area of all
tools, equipment and debris.
• Check the entire unit to
ensure it's cleanliness.

***** WARNING ******

The manufacturer does NOT
WARRANT equipment sub-
jected to abuse. Metal chips,
dust, drywall tape, paint over
spray, etc. can void warranties
and liability for equipment
failure, personal injury and
property damage.

Drain Piping
The drain should always be:

Connected or piped to an accept-

able disposal point sloped away from
the unit at least 1/8" per foot

Checked before summer operation

Periodically checked during sum-

mer operation

Preventative Maintenance
To achieve maximum performance
and service life of each piece of equip-
ment a formal schedule of regular
maintenance should be established
and maintained.

**MAINTENANCE UPDATES**

For a current copy of the Mainte-
nance Program log on to
www.firstco.com and look un-
der "Product Information"

****** WARNING ******

R-410a systems operate at
much higher pressures than
systems using former refriger-
ants. Use only equipment cer-
tified for use with R-410a.

CUT OUT THIS
SECTION

FOLD FOUR
FLANGES OUT, 90°

TRIM AWAY
INSULATION HERE
TO AVOID FILTER
BINDING

RIGHT HAND CL
FAN COIL

RETURN AIR OPENING WITH
FLANGES FOLDED OUT

DRAIN PAN FITTINGS

REFRIGERANT
FITTINGS

FILTER COVER

POWER SUPPLY
KNOCKOUTS, L/R

LOW VOLTAGE, L/R

HEATING ELEMENTS

LEFT HAND CL
FAN COIL