11

INSTALLATION REQUIREMENTS

Fig. 11-3

CORRECT

PLACE GRILL SO PREVAILING

WIND BLOWS TOWARD FRONT

OF GRILL

YOU MUST PROTECT

REAR OVEN VENT FROM

PREVAILING WIND

Rear oven lid vent

INCORRECT

Fig. 11-2

The control panel MUST remain removable for
servicing and air shutter adjustment (see PARTS
LIST).

THIS UNIT MUST NOT BE LOCATED IN A FULLY
ENCLOSED AREA OF ANY KIND.

ENSURE PROPER COMBUSTION AIR AND
COOLING AIRFLOW

Proper airfl ow (Fig. 11-1) MUST be maintained for
the grill to perform as it was designed. If airfl ow
is blocked, overheating and poor combustion will
result. Do not block the 1" (2.5 cm) front air inlet
along the bottom of the control panel or more
than 75% of the cooking grid surface with pans
or griddles.

Note: The 1" (2.5 cm)

front air space
a l s o a l l o w s
access to the
drip tray.

Fig. 11-1

- Ventilation

CAUTION: Wind blowing into or across the rear

oven lid vent (Fig. 11-2) can cause
poor performance and/or dangerous
overheating. Orient the grill so that the
prevailing wind blows toward the front
of the grill (Fig. 11-3).

GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" (17.78 cm) water
column (w.c.), minimum 5" (12.7 cm), maximum 10

1

/

2

" (26.7 cm). For propane gas - normal 11" w.c.,

minimum 10" (25.4 cm), maximum 13" (33 cm).

REV 0 - 1412031405

L-C2-453