beautypg.com

Grill maintenance and safety information – Fire Magic Choice Built-In Grill C430i, C540i User Manual

Page 8

background image

8

1. The outdoor grill and surrounding area MUST

remain clear of fl ammable substances such as
gasoline, yard debris, wood, etc.

2. The airfl ow through the vent space located below

the control panel must remain unobstructed.

3. When using propane gas:

a. The required ventilation openings in the

enclosure must be clear of debris.

b. The propane cylinder, regulator, and

rubber hose must be in a location not
subject to temperature above 125° F (51°
C).

4. The fl ames on each burner burn evenly along

the entire burner with a steady fl ame (mostly
blue). If burner fl ames are not normal, check

and clean the orifi ce and burner/venturi tubes
for insects and insect nests. A clogged tube can
lead to a fi re beneath the grill. A proper fl ame
pattern will ensure safe operation and optimal
performance. Adjust the air shutter as needed
(see AIR SHUTTER ADJUSTMENT).

5. The in-line gas valve or gas cylinder valve must

always be shut OFF when the grill is not in use.

6. The drip collector holes must be clear and

unobstructed. Excessive grease deposits can
result in a grease fi re.

GRILL MAINTENANCE AND SAFETY INFORMATION

WARNING: NEVER cover the entire cooking or grill surface with griddles or pans. Overheating will occur, and

burners will not perform properly when combustion heat is trapped below the cooking surface.

CAUTION: NEVER spray water on a hot gas unit.

The grill serial identifi cation number is located on the underside of the drip tray handle. It

is recommended that the drip tray fi rst be removed and cleaned / emptied of its contents,

then turned over to view.

REV 2 - 1406021438

L-C2-405