beautypg.com

Model specifications, Top view, Front view – Fire Magic Choice Built-In Grill C430i, C540i User Manual

Page 6: Non-combustible cabinet cut-out dimensions

background image

6

MODEL SPECIFICATIONS

COUNTERTOP OVERHANG

The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends beyond
the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be
created exposing the forward portions of the left and right side grill fi re walls. See illustrations above.

Important:

FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and cross-

ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane bottles. See

the ENCLOSURE REQUIREMENTS section for details.

TOP VIEW

Countertop

Lower support

Countertop
overhang

Control panel

NON-COMBUSTIBLE

CABINET CUT-OUT

DIMENSIONS

Fig. 6-1

FRONT VIEW

B

C

D

See next page

for substrate

considerations

Countertop
overhang

X

TOP VIEW

SIDE VIEW

Countertop

overhang

(Control

panel)

(Countertop)

Y

1

/

4

"

Clearance

(Overhang)

X= D-B÷2

Y= Total
Countertop
Overhang

A

Control

panel

Check clearance for

control panel removal

REV 2 - 1406021438

L-C2-405

MODEL SPECIFICATIONS TABLE

Table 1

C430i

C540i

Main burner BTU
N/P orifi ce drill size

20,000 x 2

#44/#55

20,000 x 3

#44/#55

Optional insulating liner model #

23130-50

23150-50

A Countertop to unit bottom cut-out*

12"

12"

B Side to side non-combustible cut-out*

25-1/2"

32"

C Front to back non-combustible cut-out*†

19-1/2"

19-1/2"

D Control panel width non-combustible cut-out

27"

33"

*Note:

If using an insulating liner, consult liner instructions for counter cut-out dimensions
and installation.

† Includes any substrate at front wall of enclosure (in the area the rear of the control panel

is to sit fl ush against). See SUBSTRATE section on next page.

‡ Only applicable for non-combustible enclosures that have countertops with an overhang

(see illustration and section below).