beautypg.com

Dukane Projector 8920H-RJ User Manual

Page 73

background image

73

Phenomenon

Cases not involving a machine defect

Reference

page

Pictures appear

dark.

The brightness and/or contrast are adjusted to an

extremely low level.

Adjust BRIGHTNESS and/or CONTRAST settings to a

higher level using the menu function.

27

The ECO MODE function is working.

Select NORMAL for the ECO MODE item in the SETUP

menu.

35

The lamp is approaching the end of its product

lifetime.

Replace the lamp.

62, 63

Pictures appear

blurry.

Either the focus and/or horizontal phase settings are

not properly adjusted.

Adjust the focus using the focus ring, and/or H PHASE

using the menu function.

19, 31

The lens is dirty or misty.

Clean the lens referring to the section “Caring for the lens”.

67

RS-232C does

not work.

The SAVING function is working.

Select NORMAL for STANDBY MODE item in the SETUP

menu.

36

The COMMUNICATION TYPE for the CONTROL port is

set to NETWORK BRIDGE.

Select OFF for COMMUNICATION TYPE item in the

OPTION - SERVICE - COMMUNICATION menu.

48

Network does

not work

The SAVING function is working.

Select NORMAL for STANDBY MODE item in the SETUP

menu.

36

NETWORK

BRIDGE

function does

not work

The NETWORK BRIDGE function is turned off.

Select NETWORK BRIDGE for COMMUNICATION TYPE

item in the OPTION - SERVICE - COMMUNICATION menu.

48

Schedule

function does

not work

The SAVING function is working.

Select NORMAL for STANDBY MODE item in the SETUP

menu.

36

Troubleshooting

• Although bright spots or dark spots may appear on the screen, this

is a unique characteristic of liquid crystal displays, and it does not constitute or

imply a machine defect.

NOTE

Phenomena that may be easy to be mistaken for machine defects (continued)

This manual is related to the following products: