Introduction 

Elegantly simple yet packed with an advanced feature set, the FiberPlex Technologies, FOI(TD)‐7280 is a 
powerful problem solver when it comes to routing audio. The unit converts line level, stereo analog audio to 
fiber for long or short haul transport. In addition to the audio, a multi‐format serial data connection and a 
bidirectional pair of contact closures are included.  

Key Features 

Audio Interface: 

o

Supports Balanced and Unbalanced Audio I/O 

o

High Quality 24‐bit audio 

o

Ultra Wide 20 Hz to 45 kHz Frequency Response 

o

Supports Ultrasonic Signaling 

Serial Interface: 

o

RS‐232, RS‐422, RS‐485 (2/4 wire) 

o

Data Rates from 0 to 1 Mbps 

Contact Closures: 

o

‘Form C’ Contacts 

o

Supports Push to Talk 

Advanced Routing: 

o

Point to Point 

o

Broadcast Mode 

o

Intercom/Loop 

o

Multichannel Add/Drop 

Power: 

o

TD includes power adapter as well as a 3‐position Phoenix™ connector 

Differences between FOI‐7280 and TD‐7280 

Functionally, the FOI‐7280 and TD‐7280 are identical. The only differences are the packaging and power 
supply. The FOI‐7280 is part of the FOI line of products designed for ruggedized mil applications. It is housed in 
the familiar FOI shielded can enclosure. For standalone applications it can be powered by adding a PSQ‐4909 
AC supply or a PSQ‐4920 DC power supply (not included). Optionally, up to 8 FOI units can be mounted on 
CMA chassis adapters and installed in an RMC‐3101 or RMC‐2101 rack mount chassis. The units are powered 
redundantly by a common back plane connection. 

The TD‐7280 is housed in the commercial ‘Throw Down’ packaging. This version is designed to be a work horse 
unit in various commercial and industrial environments. It is powered either by a 9VDC ‘Wall Wart’ style 
supply (included) or via bussed power supplied through an integrated three pin Phoenix™ connector. Up to six 
TD‐7280 units can be installed in the optional 1U TDR‐01 rack shelf. 

Getting Started 

Initial Inspection 

Immediately upon receipt, inspect the shipping container for damage. The container should be retained until 
the shipment has been checked for completeness and the equipment has been checked mechanically and 
electrically. If the shipment is incomplete, if there is mechanical damage, or if the unit fails to operate notify 
FiberPlex and make the shipping materials available for the carrier's inspection. 

Set Up (Basic Point to Point) 

1)

IMPORTANT 

Set the ‘Network’ setting on the 

Configuration Switch according to diagram on 
right, see ‘Connection Details’ for more 
information 

2) Connect all external wiring to the Interface 

Connector, see ‘Interface Details’ for more 
information

 

3) Connect fiber between units linking the TX from 

the first unit to the RX of the second

 

4) Connect power 

 

 

Switch settings shown for standard Point to Point 

Setup. First Unit is Point to Point Master and 

Second Unit is set to Slave.  

The FOI(TD)‐7280 WILL NOT WORK reliably with 

both modules configured as Slave.