Instructions for installation and use
Installation Instructions
Installation, electrical connection and the first use should only be perfor-
med by a qualified person.
Distances
The distance from the lower edge of the appliance to the floor should not
be less than 50 mm. There should also be a distance of at least 100 mm
at the sides, e.g. to a furniture, and above (see Fig. 2).
In bathrooms, the panel must be installed in accordance with Figure 1 in
zones 2 and 3.
The panel is a class II equipment and is splash water protected with the
IP 44 protection. The panel should not be arranged right under a fixed
connection socket. The electric installation must be equipped with a
double pole switching device with a control gap opening of at least 3 mm.
Fig.2
Fig.1
Dimensions are stated in mm
1. Marble panel
2. Mounting bracket
3. Adjusting supports
4. Wall
5. Wall plugs with spins
6. Terminal box
7. Bracket cover
Fig.3