Parameter settings, Mode temperature pre-set – Fenix HT-600 User Manual
Page 6

Parameter Settings
Under off status, press “M” button and “+”button at the same time. You be able to enter the parameter
settings. Each press of “M” button can into next item setting.
Note: If factory reset need, after select 1, please long press ON/OFF button to activate it.
01) When the temperature must be changed, temperature can be calibrated with the real temperature.
02) The low level temperature can be set (for example 15°C)
03) The high level temperature can be set (for example 45°C)
04) Selection of the sensor mode: room sensor or external sensor
05) The high level temperature buzzer can be disable or enabled. When enabled the buzzer activate when
the high level temperature is exceeded.
06) To enable or disable the programming function of the plugin thermostat. When enabled the
thermostat works as a programmable thermostat, when disabled the thermostat reacts only with the
UP and DOWN button.
07) Factory reset to set the default factory settings!
Mode Temperature Pre-set.
The Mode temperature can be set as the below following steps:
-
Press and hold the “M” button for around 3 seconds. The COMFORT mode (pic. A) display.
-
Change the mode temperature by the “+” or “-” buttons.
-
Press “M” button , the Energy-saving mode display (pic. B).
-
Change the mode temperature by the “+” or “-” buttons.
The comfort function is displayed as a
symbol (e.g. 25.5°C).
The energy-saving function is displayed as a symbol (e.g. 20.5°C).
The setup will be memorized by the EEPROM.
No.
Item
Range
Default
01
Temp. Calibration
-9 ~+9 °C
0°C
02
Low Temp. Limit
0’C ~ 25 °C
10°C
03
High Temp. Limit
20’C ~ 60 °C
45°C
04
Sensor Select
1: External 0: Internal
1
05
Buzzer Sound Alarm
0: Disable 1: Enable
Enable
06
PRG Function
0: Disable 1: Enable
Enable
07
Factory Reset
0: NO 1: YES
0
08
Software Version
1045
Pic.B