beautypg.com

Description and connection – Fenix ADSV User Manual

Page 8

background image

8

1. Description and connection

The heating cables should be connected to a 230V, 50Hz electric network. Degree of protection: IP67.

ADSV cables have protective braiding. The cable's protective braiding meets the standards required of

metal grid or metal shield and provides increased protections in spaces where that is required
(bathroom, laundry, etc.) The protective braiding is to be connected to the PE conductor or to a
protective grounding connection.

2. Use for floor heating in residential buildings, houses, workshops,

and restrooms

If the floor heating is intended to be used to warm the floor surface for short intervals, we recommend

that the heating cable be installed close to the floor surface within the upper limit of the recommended
outputs W/m

2

.

If the floor heating is to be used to heat a room, it is necessary to know the thermal loss value for the

building to select the most suitable heating system. The installed output should correspond to a
multiple of 1.2 to 1.4 times the calculated thermal loss due to the maximum recommended outputs
(see table below). An additional heating device must be used (for example, converter ECOFLEC or
ATLANTIC).

RECOMMENDED AND MAXIMUM OUTPUTS

When cables are to be installed under tiles into the adhesive sealing cement, the space between them
should not be more than 100 mm or less than 40 mm.




INSTALLATION UNDER FLOOR TILES INTO ADHESIVE
SEALING CEMENT, SO-CALLED THIN-LAYER FLOORS

Please read first the General Terms and Conditions.

To allow for expansion around the periphery of the room between the baseboards and the floor tiles,

use an expansion profile or fill the spaces with silicone sealing cement.

FLOOR COVERING
ROOM

RECOMMENE
DED FLAT
OUTPUT
W/m

2

MAXIMUM
FLAT OUTPUT
W/m

2

RECOMMENEDED
LENGHT OUTPUT
W/m

POZNÁMKA

FLOOR TILES

80 - 120

200

10

Temperature of floor surface in rooms
occupied for long time periods may
not exceed 27°C.

FLOOR TILES IN
BATHROOM

120 -160

250

15

FLOOR TILES IN
BATHROOM

160 - 200

300

18