Cabling and Amplifier Selection

The MSE-159 and MSE-156 are designed to be used with professional power amplifiers providing the following
power outputs:

MSE-159/MSE-156

1500W/channel into eight ohms

2 x MSE-159/MSE-156

3000W/channel into four ohms


It is good practice to use an amplifier equal to the program power rating of the loudspeaker – so as to retain
sufficient headroom and good dynamic range. Care should be taken during operation to avoid amplifier clipping,
and it is recommended that suitable limiters are applied in order to keep amplifier channels clear from clipping – as

this can cause serious damage to your loudspeakers. If in doubt, please contact your dealer who will be happy to
assist you in correct amplifier choice and setup.

Cabling


The MSE-159 and MSE-156 are supplied as standard with Neutrik SpeakON

TM

NLT4MP connectors, wired pin 1+/1-.

It is recommended that the resistance of your cable is less than one tenth of the nominal system impedance.
Given below are the recommended maximum cable lengths for different cross-sections and impedances.

Conductor Cross Sectional Area

Maximum Recommended Cable Length

4 ohms

8 ohms

16 ohms

1.0mm

2

11m

22m

44m

1.5mm

2

17m

34m

68m

2.0mm

2

22m

44m

88m

2.5mm

2

29m

58m

116m

4.0mm

2

44m

88m

176m

6.0mm

2

66m

132m

264m

Pins 2+/2- on the SpeakON

TM

connectors are wired together to allow link-through with 4-core cables.



A small power amplifier working too hard is more likely to damage a loudspeaker than a large power amplifier