6 Installation & Mounting / Front Panel Controls

INSTALLATION AND MOUNTING NOTES

this equipment is designed to be installed in a standard 19” rack. When the unit is mounted above or below other

rack mounted equipment, a 1U space should be left between the unit and the other equipment to allow ambient

air flow between the units.
Connect the AC line cord to an appropriate source of 120 volt, 50/60 Hz AC power. the mqm6000L is always on

once the AC power cord is connected to its power source.

Front Panel Controls

F1, LCD Display – this display presents the selected menu screen and the parameter settings. the backlight

in the display is on when power is applied. When not in adjust mode the qAm output symbol rate in mbits

per second is displayed. Pressing the down button shows the buffer status as a percentage of its maximum

capacity. the left percentage represents the current buffer status and the right number represents the maximum

percentage of buffer capacity that was reached since the unit was last programmed. if either of these numbers

reaches 100%, it is probable that too much data is being processed which will likely result in missed frames, video

or audio breakup, or other anomalies in the output signal.
Repeatedly pressing the down button will toggle back and forth between the buffer status screen and the qAm

output symbol rate screen. Pressing the up button causes the display to show the firmware version number.

Repeatedly pressing the up button will cause the display to toggle back and forth between the firmware version

number and either the qAm output symbol rate screen or the buffer status screen, which ever one is selected

with the down button.
F2, ENTER button – Use the eNteR button to enter the adjust mode or to save and load a new setting or settings

after adjustment. Hold for 2 seconds until the bottom line of the display starts to flash to enter the adjust mode. After

entering the adjust mode, momentarily pressing the eNteR button again will load and save any settings that may

have been changed using the f5 & f6 buttons.
F3 & F4, Left and Right Buttons – Use the left and right arrow buttons to navigate from screen to screen to view

a parameter setting. these buttons are operational in the view mode or the adjust mode. Using only these buttons

will not change any parameter settings. After a short period of button inactivity, the default display will be returned.
F5 & F6, Up and Down Buttons – Use the up and down arrow buttons to change the value of a viewed parameter

setting. the unit must be in the adjust mode with the display flashing in order for these buttons to become active for

changing a parameter setting. if the unit is not in the adjust mode, pressing the up button will display the firmware