[1] Power-save mode: After approximately 3 minutes of no interaction, the unit will enter into its power-save
mode by turning off all front-panel LeDs and displays. the dot of the 2-digit LeD will remain lit to indicate unit
is powered and operating normally. Pressing any button will bring the unit out of power-save mode and current
channel and modes will be displayed.
[2] Unit Reset: Holding the RF Mode and Baud Rate buttons simultaneously for 5 seconds will reset the unit.
All three digits of the unit will display a countdown from 5 to 0 and then reset. After reset, the unit will return to its
last programmed state. A reset is required after a firmware or software update.
[3] Alerts: the DtS860 has 2 alerts to indicate a non-typical condition or error in operation. the 1-digit LeD will
display ‘e’. the 2-digit LeD will display the condition number as described below.
01 E – internal communication error between microcontroller and decoder. Perform a unit Reset or disconnect/
reconnect the power to correct this.
02 E – No signal error. tV/monitor screen will display ‘No signal’. Verify that incoming Rf is connected and
desired/undesired channels are at recommended levels. Press the SNR button and confirm that signal-to-noise
ratio is greater than 20 for 8VSB, 25 for QAm 64, 30 for QAm 256. Also confirm that the correct frequency plan,
modulation and baud rate have been set.