beautypg.com

Installation specifications, Install a support platform in the cabinet, Electrical power supply requirements – Dacor MWDH27 User Manual

Page 8

background image

6

Installation Specifications

Install a Support Platform in the

Cabinet

Provide a platform (100 lb. load capacity) within the cabinet
upon which the warming drawer will be supported. The
platform must be installed level and straight. The top edge
of the platform must be flush with the cutout at the front of
the cabinet. There are no provisions to level the warming
drawer after it has been installed. 3/4” (19 mm) thick
plywood is recommended.

NOtE:

If the drawer is not installed in a level fashion, the
drawer may slide open on its own or may not seal
tightly, allowing heat to escape and resulting in poor
warming drawer performance.

Support

platform

Chassis

face

The warming drawer is supplied with a power cord

terminated by a three-prong plug. Plug it directly into a
dedicated, grounded, three prong, electrical outlet. Do
not use an extension cord.

The correct voltage, frequency and amperage must be

supplied to the electrical outlet from a grounded, single
phase circuit that is protected by a properly sized circuit
breaker or time-delay fuse.

The required voltage, frequency and amperage ratings

are listed on the appliance data plate. The data plate
is located inside the chassis drawer opening on the left
side. Remove the drawer to expose it.

If the power supply requirements shown above do not

agree with those listed on the product data plate, use
the requirements on the product data plate.

It is the owner’s responsibility to ensure that the

electrical outlet is installed by a qualified electrician.
The electrical installation must comply with the latest
revision of the National Electric Code ANSI/NFPA 70
and local codes and ordinances.

If the electrical service provided does not meet the

product specification, or does not conform to the NEC
or local standards, do not proceed with the installation.
Call a licensed electrician to correct the electrical
service before proceeding.

Be certain to locate the electrical outlet in an

accessible location, so that the warming drawer may
be easily unplugged in the event that service becomes
necessary.

Electrical Power Supply

Requirements

Nominal Electrical Supply Requirements

120 Vac, 60 Hz, 15 Amp. dedicated circuit

The warming drawer is supplied with a 40” (1016 mm)
power cord with a three prong grounded plug.

total Connected Load

0.5 kW (4 Amp.)

Three-Prong Plug

Three-Prong

Grounded Outlet

This manual is related to the following products: