Quad Amp Hardware Reference Manual
Installation
27
During this tuning process, P2Setup also determines the commutation parameters and commands the
PMAC appropriately.
Power Block Option
Continuous Hp
Continuous
Current (A)
Peak Current
2 Sec (A)
Max ADC Value
208/230 VAC
5 0.75
2 5
6.25
6 1.5
4
11
13.75
7 2
5
15
18.75
8 3
7
21
26.25
9
5 15 36 45
10 7.5
20
54
67.5
11 10 25 75
93.75
12 15
35
100
125
13 20
50
150
187.5
14 30
75
200
250
380/460 VAC
15 2
2.5
7.5
9.375
16 3
3.5
10.5
13.125
17 5
6
18
22.5
18 10
12.5
40
50
19 20 25 75
93.75
20 30
35
100
125
Enter Max ADC value in P2-Setup, step Current Protection. Enter Peak Current and Continuous Current values, if
applicable.
F.A.Q
1. PWM Frequency – The default value suggested by P2Setup (4.5 kHz) works well for most
applications. If more heat is generated in the motor than the amplifier, using a higher PWM frequency
may assuage this problem.
a. Set up a Lower Voltage Motor with the Quad Amplifier. The following steps should be
followed in P2Setup to ensure that the appropriate voltage is used for the motor while using the
Quad Amplifier:
After PWM frequency and Phase and Servo frequencies have been set up successfully, click the
Terminal Window tab.
Modify Ix66 using the following formula:
Voltage
_
Bus
_
Amp
_
Quad
voltage
_
peak
_
Motor
*
900
I
66
Ix
=