Changing options using long form setup, Menu 1. basic features in most indicators, Menus and calibration – Digi-Star EZ400 User Manual
Page 17
Menus and Calibration
D3655-US Rev E
EZ400 User’s Manual
13
MENUS AND CALIBRATION
The Indicator has optional settings that allow flexibility in the way that the scale
is used and data is collected.
Changing Options Using Long Form Setup
Enter Long Form Setup by holding and for three seconds.
Press to select menu 1, 2, 3 or 4.
Press to advance to desired parameter.
Press to select proper setting.
Press to save setting and advance to next parameter.
Hold and press to return to indicator operation.
Default settings from the factory vary with options and due to customer
preferences.
SETTING
[display]
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
MENU 1. BASIC FEATURES IN MOST INDICATORS
LANGUAGE
(langag)
English
Dutch
French
German
Italian
Portuguese
Spanish
Danish
Hungarian
Spanish
[ENGLSH)
[NEDERL]
[FRANCS]
[DEUTSH]
(ITAL]
(PORT]
(ESPAN]
(DANSK]
(MAGYAR]
(VESTA]
Select language to be displayed.
DISPLAY RATE
(0 rate)
I,
2
,3,4
Update display times per second.
ZERO TRACK
(ztrack)
ON/
OFF
If ON -zero track adjust balance for
buildup of snow & mud.
WEIGH METHOD
(W mthd)
I=General,
2=Fast,
3=Slow,
4=Lock-On
Select weigh method