Dayton, Generator – Dayton 2ZRP9 User Manual
Page 8
8
E
N
G
L
I
S
H
Dayton Operating Instructions and Parts Manual
Dayton
®
Generator
2ZRP8, 2ZRP9
hear or feel a distinctive “click”. IF
THE GFCI FAILS TO RESET PROPERLY,
DO NOT USE EITHER OUTLET OF THE
DUPLEX RECEPTACLE. Have the unit
serviced by an authorized Dayton
Customer Service Representative
immediately.
3. High vibration or severe mechanical
shock loads may cause the GFCIs to
trip. IF EITHER GFCI TRIPS BY ITSELF
AT ANY TIME, reset it and perform
test procedures 1 and 2.
4. Repeat steps 1-3 for the second GFCI.
ALTHOUGH THE
ABOVE TEST
PROCEDURES WILL INDICATE PROPER
GFCI OPERATION ON AN UNGROUNDED
OR IMPROPERLY GROUNDED
GENERATOR, THE GENERATOR MUST
STILL BE GROUNDED PER THE
GROUNDING INSTRUCTIONS LISTED ON
PAGE 14 FOR THE GFCI TO FUNCTION
PROPERLY AND PROTECT THE USER FROM
ELECTRICAL FAULTS.
eVaPORatiVe eMissiOn cOMPOnents:
The unit you have purchased includes
the following components that are in
compliance with 2008 California Air
Resources Board Evaporative Emission
Standards;
1. Fuel Hose
2. Fuel Hose Fittings
These components should be inspected
on a daily basis for cracks, leaks, and
abnormal wear. If cracking, leaks or
abnormal wear has occurred, the
components should be replaced
immediately.
IDLE cOnTROL ADJUSTMENT:
NOTE: The automatic idle speed is set
between 2640 and 2940 RPM.
The idle speed has been pre-set at
the factory and should rarely require
readjustment. We recommend that
all adjustments of this nature be
made by a Dayton Customer Service
Representative.
Erratic idle operation of the engine
usually indicates a need for carburetor
adjustment to provide a smooth idle.
The idle control will not function
properly when the idle speed is
below the recommended limits or the
carburetor is improperly adjusted.
ENGINE:
The engine for this generator is
Maintenance Chart
Check Fuel
X
Check Engine Oil
X
Check for loose or lost nuts and bolts
X
Check for leaks
X
Check cylinder and head fins for
dust and dirt
X
Check battery electrolyte level
X
Check fuel lines (replace if necessary)
X
Clean air cleaner foam element (**)
X
Tighten nuts and bolts (*)
X
Change engine oil
X
Clean fuel filter
X
Replace air cleaner paper element
X
Clean dust and dirt from cylinder and
X
cylinder head fins (**)
X
Clean and regap spark plug
X
Add fuel stabilizer
X
Run unit dry
X
* Perform these operations after the first 5 hours of use, then at the recommended intervals.
** Service more frequently under dusty conditions.
NOTE: These items must be performed with the proper tools. See your Dayton Customer Service Representative
for service, unless you have the proper equipment and mechanical proficiency.
Procedure
Daily
Every
2 hrs.
Every
100 hrs.
Every
200 hrs.
Before
Storage