Jumper settings, Chapter 2 jumper settings – DFI CD101-N User Manual
Page 12

www.dfi .com
12
Chapter 2 Hardware Installation
Chapter 2
Jumper Settings
Clear CMOS Data
If you encounter the following,
a) CMOS data becomes corrupted.
b) You forgot the supervisor or user password.
you can reconfigure the system with the default values stored in the ROM BIOS.
To load the default values stored in the ROM BIOS, please follow the steps below.
1. Power-off the system and unplug the power cord.
2. Set JP4 pins 2 and 3 to On. Wait for a few seconds and set JP4 back to its default setting,
pins 1 and 2 On.
3. Now plug the power cord and power-on the system.
JP4
2-3 On:
Clear CMOS Data
1-2 On: Normal
(default)
3
1
2
3
1
2
Power-on Select
1-2 On:
Power-on via power button
(default)
2-3 On:
Power-on via AC power
JP10
3
1 2
3
1 2
JP10 is used to select the method of powering on the system. If you want the system to
power-on whenever AC power comes in, set JP10 pins 2 and 3 to On. If you want to use the
power button, set pins 1 and 2 to On.
When using the JP10 “Power On” feature to power the system back on after a power failure
occurs, the system may not power on if the power lost is resumed within 5 seconds (power
flicker).
Note:
In order to ensure that power is resumed after a power failure that re covers within a
5 second period, JP10 must be set to pins 2-3 and the “AC Power Lose” in CMOS is
set to “On”.