beautypg.com

Chapter 2, Power-on select, Lvds panel select – DFI CD951-C2800 User Manual

Page 12

background image

www.dfi .com

12

Chapter 2 Hardware Installation

Chapter 2

Power-on Select

1-2 On:

Power-on via power button

(default)

2-3 On:

Auto power-on

JP5

3

1

2

3

1

2

JP5 is used to select the method of powering on the system. If you want the system to

power-on whenever AC power comes in, set JP9 pins 2 and 3 to On. If you want to use the

power button, set pins 1 and 2 to On.

When using the JP5 “Power On” feature to power the system back on after a power failure

occurs, the system may not power on if the power lost is resumed within 5 seconds (power

flicker).

LVDS Panel Select

SW2

SW2 is used to select the resolution of LVDS panel on the system.

LVDS Panel Select

Channel

SW2

800x600

6/18 bit

Single

1-4 On

1024x768

6/18 bit

Single

2-4 On, 1 Off

1024x768

8/24 bit

Single

1,3,4 On, 2 Off

1280x768

6/18 bit

Single

3-4 On, 1-2 Off

1280x800

6/18 bit

Single

1,2,4 On, 3 Off

1280x960

6/18 bit

Single

2,4 On, 1,3 Off

1280x1024

8/24 bit

Dual

1,4 On, 2,3 Off

1366x768

6/18 bit

Single

4 On, 1-3 Off

1366x768

8/24 bit

Single

1-3 On, 4 Off

1440x900

8/24 bit

Dual

2-3 On, 1,4 Off

1400x1050

8/24 bit

Dual

1,3 On, 2,4 Off

1600x900

8/24 bit

Dual

3 On, 1,2,4 Off

1680x1050

8/24 bit

Dual

1-2 On, 3-4 Off

1600x1200

8/24 bit

Dual

2 On, 1,3,4 Off

1920x1080

8/24 bit

Dual

1 On, 2-4 Off

1920x1200

8/24 bit

Dual

1-4 Off

Note:

In order to ensure that power is resumed after a power failure that re covers within a

5 second period, JP9 must be set to pins 2-3 and the “AC Power Lose” in CMOS is set

to “On”.