Assembly and installation / operation – Dexaplan CA 616 User Manual
Page 9
9
GB/IE
o Ensure that the sabotage contact r (on the rear of the
housing) is pressed and lies flush against the installation
site surface.
Motion detector
Double-sided adhesive strips
o Attach the motion detector using the two double-sided
adhesive strips.
or
the mounting screws and dowels
c
Danger! Avoid injury when drilling out the mounting
holes p on the rear o of the motion detector housing!
m
Attention! Make sure that the motion detector is not dam-
aged in any way during the drilling of the mounting holes!
o Unlock the front of the housing of the motion detector
using a small flat-headed screwdriver (see Fig. G) and
separate it from the rear of the housing o.
o Drill out the two preformed breakthrough points p to
form the mounting holes using a hand drill / electronic
screwdriver to a diameter of 2 mm. The holes may be
side by side or one under the other.
o Mark the two mounting holes p at the selected instal-
lation position.
o Drill the two holes for the two dowels (22 x mm) and
insert the dowels into the holes.
o Mount the rear of the housing o by screwing the two
mounting screws (22 x 3 mm) into the dowels.
o Engage the front of the housing with the top edge of
the rear of the housing o. Then pivot the front fully
down until the front engages completely with the rear.
Operation
m
Attention! To avoid the risk of hearing damage: wear
ear protection and ensure that no people or animals
are standing within a radius of 10 m of the device.
“Arming” (activating) the compact alarms system
o Press key 1 on the keypad R twice. You have now
entered the user code (factory setting 11).
o Then press key E on the keypad R once. You have
now confirmed the user code.
Exit delay
The compact alarm system emits a pip sound, the LED W
(green) illuminates for approx. 30 seconds. For the period of
the exit delay of approx. 30 seconds you may cross the de-
tection range of the motion detector without triggering the
alarm of the compact alarm system.
If motion is detected during the exit delay period then you
will hear a short pip sound and the 30 second exit delay will
restart. After the exit delay has expired the LED W (green)
goes out. The system is armed / activated.
“Disarming” (deactivating) the compact alarm system
Entry delay
If the motion detector detects a motion then you will hear a
short pip sound and an entry delay of approx. 8 seconds is
activated.
o You have to enter the user code within the period of the
entry delay to disarm the device.
o Press key 1 on the keypad R twice. You have entered
the user code (factory setting 11).
o Then press key E on the keypad R once. You have
now confirmed the user code.
The compact alarm system is disarmed / deactivated
and emits a 2-pip sound to confirm it.
If you have not entered the correct user code then the
compact alarm system emits a 4-pip sound.
Alarm
The alarm is triggered by the following circumstances
(assuming the compact alarm system has been armed):
o The passive infrared motion detector has detected a
motion and the user code has not been correctly entered
within the entry delay period (8 seconds).
Assembly and installation / Operation
KOE358_GB_IE_FI_SE_NO_Content_619 9
24.10.2006 11:16:18 Uhr