beautypg.com

Safety advice – Dexaplan CA 616 User Manual

Page 5

background image

GB/IE

Front external siren (see Fig. D)
q

Speaker (external siren)

w

Cable (including socket connector) (external siren /

control unit)

Rear external siren (see Fig. E)
e

Top mounting point

e

a Bottom mounting point

r

Sabotage contact

t

Mounting screws (4 x)

Battery compartment external siren (see Fig. F)
y

Battery holder

Front motion detector (see Fig. G)
u

Infrared sensor

i

Cable (motion detector / control unit)

Rear motion detector (see Fig. H)
o

Housing rear

p

Preformed breakthrough points for attachment holes

Technical information

Control unit:
Operating voltage:

6 V

Stand-by current:

approx. 0.1 mA

Alarm current:

max. 120 mA

Power supply:

4 x batteries 1. V type LR6
(mignon / AA, alkaline) (not included)

Battery operating
life (stand-by):

approx. 1 year

Battery warning:

4. V

Entry delay:

8 seconds

Exit delay:

30 seconds

Sabotage protection: against dismantling
Internal siren:

approx. 100 dB(A) at a distance of 1m

Alarm time:

approx. 60 seconds

LED:
Battery status warning: red
Exit delay:

green

Speaker:

pip sound key (to change the user
code)

melody (confirmation of own user
code)

Operation:

3 x 4 matrix keypad, user code, one
to ten digits

Operating temperature: approx. -10 °C to +39 °C
Dimensions:

6. x 9.0 x 4.0 cm

Housing material:

ABS plastic

Motion detector:
Sensor:

passive infrared

Detection range:

approx. 90°

Range:

approx. 6 m at 20 °C

Operating temperature: approx. -10 °C to +39 °C
Dimensions:

4.1 x 6.0 x 3.2 cm

Housing material:

ABS plastic

Cable length:

approx. 300 cm (including socket
connector)

Sabotage protection: against severing the cable

External siren:
Operating voltage:

6V

Current input:

max. 120 mA

Power supply:

4 x battery 1. V type LR6 (mignon / AA,
alkaline) (not included)

Sabotage protection: against severing cable and disman-

tling

Piezo alarm:

approx. 10 dB(A) at 1m distance

Alarm time:

sabotage alarm: approx. 120 seconds

motion detection: approx. 60 seconds

Cable length:

approx. 300 cm (including socket
connector)

Operating temperature: -10° to +39 °C
Dimensions:

6. x 9.0 x 4.0 cm

Housing material:

ABS plastic

Safety advice

KOE358_GB_IE_FI_SE_NO_Content_615 5

24.10.2006 11:16:17 Uhr