Datatek DT-7000 Utilities User Manual
Page 15

U t i l i t i e s - D T 6 b a c k u p , D T 6 r e l o a d , D T 6 u p g r a d e – R e l e a s e 3 . 0
D T 7 b a c k u p , D T 7 r e l o a d
02/04/10
Datatek Applications Inc.
15
4.4.2 U
SAGE FOR
BNS
E
NDPOINTS
(C
OMM
K
IT
/IP-C
OMM
K
IT
C
ONNECTED
S
UPPORT
H
OST
P
LATFORM
)
Syntax: dt7reload [-v] [-d] [-V] [–p
[–sn
-sp
Where:
-v Print
Version
of
the Utility, then exit
-d
Connection Debug (verbose) print enable
-V
Abbreviated Debug (verbose) showing runtime progress of the utility
-p
Password for logging into the DT product (Default is “initial”)
-P
As an alternative to supplying the –p
the unit password when it is needed. The password is not echoed.
-sn
Name or IP address of the FTP server from which to retrieve the backup file. If this is
not supplied, the server running the utility is used as the FTP server.
-sl
The login on the FTP server from which to retrieve the backup file. If this is not
supplied, the user running the utility is used as the login for FTP.
-sp
The password for the login on the FTP server from which to retrieve the backup file
-sP
As an alternative to using the –sp
the server password when it is needed. The password is not echoed.
The BNS dialstring of the DT product console
The filename including its directory string, if necessary, on the FTP server containing
the backup information.
One of the following options: the
–sp
option or the
–sP
option must be given in the command
line. The password for logging into the FTP server that retrieves the backup file is either specified on the
command line or prompted with echo off.