beautypg.com

Lamp replacement – Dukane Projectors User Manual

Page 9

background image

7

Lamp in projector:

SP2xxx — 2000 lumen, uses a 360 watt EYB lamp, Dukane Part

Number 456-186.

SP4xxx — 4000 lumen, uses a 410 watt FXL lamp, Dukane Part

Number 456-192.

SP3xxx — 3000 lumen, uses a 360 watt ENX lamp, Dukane Part

Number 458-188.

LAMP REPLACEMENT

WARNING

Lamp and adjacent metal parts are hot. Allow lamp to cool

before replacing. Glass components may shatter.

Handle carefully.

Lamp replacement, SP2xxx units:
1. Open unit stage by depressing the latch tabs on front of stage

and lifting (Step 1). Remove the stage.

2. Carefully pull out used lamp. Take caution since it may be hot.

Allow time to cool (Step 2).

3. Push new lamp in socket until firmly seated. Avoid skin oil on

bulb. Hold lamp with a cloth, tissue or gloved hand.

4. Replace stage by aligning rear edge and then pushing down the

front until it locks into place.

FOR 2000 LUMEN MODELS —

Open stage.

S

TEP

1 —