beautypg.com

Troubleshooting – Dukane Projectors User Manual

Page 11

background image

9

3. Squeeze the lamp retainer clip to

free lamp. Carefully pull up the used
lamp. Take caution since it may be hot.
Allow time to cool (Step 3).

4. Place new lamp in socket.

Push down until firmly seated.
Avoid skin contact. Oil from
skin can cause discoloration
of the lamp capsule or re-
flector. Hold lamp with a
cloth, tissue or gloved hand.

5. Engage the lamp retainer clip.

6. Close lamp cover and replace cover retainer clips. Replace the

stage by aligning rear edge and then pushing down front until
it locks in place.

Open lamp retainer clip
and pull out the lamp.

S

TEP

3 —

TROUBLESHOOTING

Symptom

Probable Cause

Solution

Neither lamp or

a. Unit unplugged

a. Plug unit into

fan operate

outlet

b. No power at wall outlet

b. Verify outlet

has power

c. Stage not closed

c. Close stage

d. Stage installed backwards

d. Install stage

correctly

e. Damaged part

e. Obtain service

No lamp, fan runs

a. Burned-out lamp

a. Replace lamp

b. Lamp changer not engaged

b. Slide changer arm

into position

c. Lamp not seated in receptacle

c. Seat lamp

New lamp installed,

a. Defective lamp

a. Try another new

lamp still not on,

lamp

fan runs

b. Defective electrical system

b. Obtain service

No fan, lamp on

a. Fan is obstructed

a. Obtain service

b. Fan motor has burned out

b. Obtain service