Installation

2-1

Section 2 : Installation



2.1

General System

Reference Drawings: Pwr/Sig Entrance, 1 Driver Display ............. Drawing A-46755

Component Locations, CH-1624V .............. Drawing A-46756

System Layout, CH-1624V.......................... Drawing A-46757

Display Mounting, CH-1624V...................... Drawing A-46774

Footing & Beam, CH-1624V........................ Drawing A-46784

Color Code, 25 Pin J-Box ........................... Drawing A-47207

Electrical Installation, CH-1624V ................ Drawing A-47270

Refer to Drawing A-46757 for a general system layout.

The general procedure for installing the CH-1624V display is as follows:

1. Select beam and footing recommendations from the table below.
2. Dig the footing holes and install beams and footings. Refer to the table in Section 2.2 for

the correct beam and footing selections.

3. Route power and signal cables to the display and control locations.
4. Mount the displays to the beams as described in Drawings A-46774 and A-46784 and in

Section 2.3.

5. Route power and signal wires into the displays as described in Drawings A-46755, A-

46756, A-47207 and A-47270 and in Section 2.4.


2.2

Beam and Footing Selection

Reference Drawing: Footing & Beam, CH-1624V .......................... Drawing A-46784

The table below contains recommendations for W-shape beams and footings to support the
display as shown in Drawing A-46784. The first column is wind velocity in miles per hour.
The distance in the second column is from the ground to the bottom of the display. The
choices from these columns depend upon the display location.

The beams listed below are beams which provide maximum wind load strength for the weight
and cost of the beams.

Wind Speed Height (ft)

Beam

Section

Footing Depth x

Diameter

70

10

W 10x19

7 ½ ftx3 ft

MPH

15

W 10x25

8 ¼ ftx3 ft

80

10

W 10x25

8 ½ ftx3 ft

MPH

15

W 10x29

9 ¼ ftx3 ft

90

10

W 14x26

9 ½ ftx3 ft

MPH

15

W 12x31

10 ½ ftx3 ft


The calculations for footing diameters and depths are based on the assumption that footings
are in undisturbed soils, not fill soils. Lateral bearing capacity of 300 psf per foot of depth in
natural grade was used to derive these figures.