POS

Interface

Installation and Operation

7-2

7. Plug the transformer (T-1118) into an outlet, and connect the output to the

power jack on the J-box.

8. Ensure that the DM-100 is up and running. Send a price change to the sign

to verify communications between the sign and the DM-100.

7.2 Configuring the DM-100 for Gilbarco G-Site

Interface

BEFORE YOU START:
The DM-100 function must be set to “GAS PRICE”. The current function of the
DM-100 is displayed during power up. To change to function, cycle power to the
DM-100, and press the <

SET FUNCTION

> key when prompted.

1. Press the

key and use the <

> and <

> keys to scroll to the “POS

SETTINGS” menu item.

POS SETTINGS
ENT TO MODIFY

↓↑

Press .

2. Select the POS type by using the <

> and <

> keys to scroll to

“GILBARCO GSITE”.

POS INTERFACE
GILBARCO GSITE

↓↑


Press .

3. Each price in the Gilbarco G-Site is uniquely identified by ‘price category’.

Each price category corresponds to the price assigned to a particular
grade/service level/price level. Use the menu shown below to configure
which price category you would like displayed on each line of the display.

PRICE CATEGORY
LINE 1 : 1

↓↑

Use the <

> and <

> keys to select a price category to be displayed on line 1 of the

sign. Press to accept the setting. Pressing when the price
category displayed is will cause the price sign to ignore POS data for this
line. (This may be useful for configuring some lines of a price sign to receive manual
price changes only).

Select a price category to be displayed on each line of the sign, and press

,
or when finished. The POS interface configuration is complete.