beautypg.com

Installation – Design Dynamics VTD-24N-JHB User Manual

Page 7

background image

www.desatech.com

114370-01E

7

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

Installation Items Needed
Before installing log set, make sure you have
the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
•. equipment.shutoff.valve*
•. test.gauge.connection*
• adjustable (crescent) wrench or pliers
•. sediment.trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative.to.test.gauge.connection..Purchase.
the optional CSA design-certified equipment
shutoff.valve.from.your.dealer..

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" diameter or greater to allow

proper gas volume to heater. If

pipe is too small, undue loss of

volume will occur.

Installation.must.include.an.equipment.shutoff.
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
NPT.tap.must.be.upstream.from.log.set.(see.
Figure 4).

IMPORTANT:.Install.equipment.shutoff.valve.
in. an. accessible. location.. The. equipment.
shutoff.valve.is.for.turning.on.or.shutting.off.
the.gas.to.the.appliance.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going.into.pipe..Excess.sealant.in.pipe.could.
result.in.clogged.heater.valves.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We. recommend. that. you. install. a. sediment.
trap in supply line as shown in Figure 4.
Locate sediment trap where it is within reach
for cleaning. Install in piping system between
fuel.supply.and.appliance..Locate.sediment.
trap where trapped matter is not likely to
freeze. A sediment trap traps moisture and
contaminants.. This. keeps. them. from. going.
into. heater. controls.. If. sediment. trap. is. not.
installed or is installed wrong, heater may
not.run.properly.

CAUTION: Avoid damage to

gas control. Hold gas control

with wrench when connecting it

to gas piping and/or fittings.

Figure 4 - Gas Connection

* Purchase the optional CSA design-certified
shutoff.valve.from.your.dealer..
**.Minimum.inlet.pressure.for.purpose.of.input.
adjustment.

Approved.Flexible.
Gas.Hose.(If.
allowed by local
codes)

CSA Design-Certified
Equipment.Shutoff.
Valve with 1/8" NPT
Tap*

From.Gas.
Meter (5" W.C.**
to 10.5" W.C.
Pressure)

3" Min.

Pipe. Cap. Tee
Nipple

Joint

Sediment.Trap

This manual is related to the following products: